{"created":"2023-06-19T07:36:18.088160+00:00","id":182,"links":{},"metadata":{"_buckets":{"deposit":"7cd021b9-1936-41fe-b777-46009f5645cc"},"_deposit":{"created_by":3,"id":"182","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"182"},"status":"published"},"_oai":{"id":"oai:kwtan.repo.nii.ac.jp:00000182","sets":["3:10"]},"author_link":["1200","1202","1206","1194","5179","5182","1196","1192","5183","5181","1205","1198","5184","1195","1208","1193","1199","1201","1197","5180","1204","1191","1207","1203"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"31","bibliographicPageEnd":"43","bibliographicPageStart":"39","bibliographic_titles":[{"bibliographic_title":"川崎医療短期大学紀要"},{"bibliographic_title":"Bulletin of Kawasaki College of Allied Health Professions","bibliographic_titleLang":"en"}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_11":{"attribute_name":"抄録(日)","attribute_value_mlt":[{"subitem_description":"90度コンプトン散乱X線スペクトルを用いて,診断用X線装置から発生するX線の実効エネルギーを評価し,その精度を従来の評価方法と比較した.90度散乱線から一次X線スペクトルに逆算すると,直接線と比較し,エネルギー分解能は若干劣るもののほぼ形状は一致した.さらに照射線量スペクトルに変換し,不規則な散乱線やノイズをカットするために17keV以上の部分についてAlによる減弱を計算し,半価層と実効エネルギーを算出した.透視条件において90度散乱線から算出した値は,直接線の値と比較し実効エネルギーで1~2%小さくなったが,ほぼ近い値が得られた.撮影条件では,測定条件を調整し計数率を1500cps以下にすると, 90度散乱線から算出した実効エネルギーはAl吸収板を用いた実測値と1%程度の誤差で一致した.これらの結果から,この評価方法は種々の診断用X線装置に応用できる簡便で有用な方法であると考えられた.","subitem_description_type":"Other"}]},"item_1_full_name_8":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"1203","nameIdentifierScheme":"WEKO"}],"names":[{"name":"MURANAKA, Akira"}]},{"nameIdentifiers":[{"nameIdentifier":"1204","nameIdentifierScheme":"WEKO"}],"names":[{"name":"NARIHIRO, Naomasa"}]},{"nameIdentifiers":[{"nameIdentifier":"1205","nameIdentifierScheme":"WEKO"}],"names":[{"name":"HAYASHI, Akiko"}]},{"nameIdentifiers":[{"nameIdentifier":"1206","nameIdentifierScheme":"WEKO"}],"names":[{"name":"AMANO, Takashi"}]},{"nameIdentifiers":[{"nameIdentifier":"1207","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ARAO, Shinichi"}]},{"nameIdentifiers":[{"nameIdentifier":"1208","nameIdentifierScheme":"WEKO"}],"names":[{"name":"HUKUMI, Atsusi"}]}]},"item_1_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.18928/00000182","subitem_identifier_reg_type":"JaLC"}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN10067901","subitem_source_identifier_type":"NCID"}]},"item_1_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0287-3028","subitem_source_identifier_type":"ISSN"}]},"item_1_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department of Radiological Technology, Kawasaki College of Allied Health Professions"},{"subitem_text_language":"en","subitem_text_value":"Department of Radiological Technology, Kawasaki College of Allied Health Professions"},{"subitem_text_language":"en","subitem_text_value":"Department of Radiological Technology, Kawasaki College of Allied Health Professions"},{"subitem_text_language":"en","subitem_text_value":"Department of Radiological Technology, Kawasaki College of Allied Health Professions"},{"subitem_text_language":"en","subitem_text_value":"Department of Radiological Technology, Kawasaki College of Allied Health Professions"},{"subitem_text_language":"en","subitem_text_value":"Department of Radiological Technology, Kawasaki College of Allied Health Professions"}]},"item_1_text_20":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_text_value":"Evaluation of Effective Energy Using Compton-Scattering Measurement of Diagnostic X-ray Spectrum"}]},"item_1_text_23":{"attribute_name":"その他(別言語)の雑誌名","attribute_value_mlt":[{"subitem_text_value":"Bulletin of Kawasaki College of Allied Health Professions"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"川崎医療短期大学放射線技術科"},{"subitem_text_value":"川崎医療短期大学放射線技術科"},{"subitem_text_value":"川崎医療短期大学放射線技術科"},{"subitem_text_value":"川崎医療短期大学放射線技術科"},{"subitem_text_value":"川崎医療短期大学放射線技術科"},{"subitem_text_value":"川崎医療短期大学放射線技術科"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"村中, 明"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"成廣, 直正"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"林, 明子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"天野, 貴司"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"荒尾, 信一"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"福見, 敦 "}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"MURANAKA, Akira","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"NARIHIRO, Naomasa","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"HAYASHI, Akiko","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"AMANO, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ARAO, Shinichi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"HUKUMI, Atsusi","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2011-01-01"}],"displaytype":"detail","filename":"KJ00007723505.pdf","filesize":[{"value":"830.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"PDF","url":"https://kwtan.repo.nii.ac.jp/record/182/files/KJ00007723505.pdf"},"version_id":"484a59b9-09d7-490c-8c39-88c614369647"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"90度散乱X線スペクトル","subitem_subject_scheme":"Other"},{"subitem_subject":"CdTe","subitem_subject_scheme":"Other"},{"subitem_subject":"診断用X線","subitem_subject_scheme":"Other"},{"subitem_subject":"Al半価層","subitem_subject_scheme":"Other"},{"subitem_subject":"実効エネルギー","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"診断用X線装置におけるコンプトン散乱X線スペクトルを用いた実効エネルギーの評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"診断用X線装置におけるコンプトン散乱X線スペクトルを用いた実効エネルギーの評価"},{"subitem_title":"Evaluation of Effective Energy Using Compton-Scattering Measurement of Diagnostic X-ray Spectrum","subitem_title_language":"en"}]},"item_type_id":"1","owner":"3","path":["10"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-01-01"},"publish_date":"2011-01-01","publish_status":"0","recid":"182","relation_version_is_last":true,"title":["診断用X線装置におけるコンプトン散乱X線スペクトルを用いた実効エネルギーの評価"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-19T07:56:16.518735+00:00"}